When you consider all of the features of Whalen units, it’s easy to see why they deliver so many benefits to contractors and users alike.
The Whalen VI Series is the only replacement chassis approved by the manufacturer to work with the existing blower section and control box wiring without modification.
As an OEM replacement, each unit is built with equal or superior components as the original without the need to supply additional information.
The refrigeration chassis includes a compressor that incorporates engineered vibration isolators installed on a heavy gauge mounting base with a mounting system to maximize vibration dampening. A sound dampening enclosure constructed of heavy gauge metal lined with acoustical insulation encases the refrigeration circuit.
The refrigeration chassis consist of the compressor, air coil, water coil, reversing valve, expansion device, receiver, filterdryer and safety controls designed for easy removal after disconnecting hoses and a polarized electrical power plug.
Units are provided with high pressure and low temperature safety controls configured in a lockout circuit to prevent damage to the compressor. The compressors are wired with either internal or external overload protective devices.
All units are provided with a 12-month warranty (from date of
ship) for all components.
Note: The replacement chassis performance is based on
providing the proper airflow through the new chassis. Existing
fan assemblies affect airflow due to corrosion and caked-on dirt.
Fan motors affect airflow due to age or improper specifications.
Cleaning/Repair/Replacement of blowers is required prior to
installation of new chassis. New fan/motor assemblies allow
your new replacement chassis to perform properly for years
to come.
The Whalen VI series Version A replacement chassis is designed for Whalen VI units produced between 1972 and 1979. Also known as “MD” or “OO”, they are available in 300, 400, 600 and 800 capacities. As part of a complete system, the Whalen VI Series Version A unit is engineered to fit into the existing cabinet space with matching electrical/water connections as the original unit.
Each unit utilizes energy efficient quality components and tested in our psychrometric room to confirm safety, reliability and performance at multiple operating conditions. The extensive list of unit features includes:
| Continuous Operating Limits | ||||||
|---|---|---|---|---|---|---|
| Mode | Ambient Air °F | Entering Air °F | ||||
| Min | Max | Min | Max | |||
| DB | DB | DB | WB | DB | WB | |
| Cooling | 60 | 100 | 75 | 63 | 100 | 83 |
| Heating | 60 | 80 | 60 | - | 80 | - |
| Unit Sizes | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model | H | W | D | CW | CH | OCH | Packaging Dimensions W × H × D |
Filter Size | Operating Weight / Shipping Weight |
| 300 | 22.8" | 13.8" | 14.0" | 11.4" | 12.0" | 20.3" | 15" × 17" × 29" | Various | 81/120 lbs |
| 400 | 22.8" | 13.8" | 14.0" | 11.4" | 12.0" | 20.3" | 15" × 17" × 29" | Various | 83/122 lbs |
| 600 | 25.5" | 13.8" | 16.0" | 11.4" | 18.0" | 26.3" | 17" × 20" × 33" | Various | 123/160 lbs |
| 800 | 25.5" | 13.8" | 16.0" | 11.4" | 24.0" | 32.3" | 17" × 20" × 33" | Various | 132/170 lbs |
| Performance Ratings | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model | Nominal Tonnage |
Rated CFM |
Minimum CFM |
GPM | Water Loop Heat Pump | Refrigerant Control |
Valve Flow Coefficient - Cv |
|||
| Cooling 86°F | Heating 68°F | |||||||||
| Capacity Btuh |
EER Btuh/W |
Capacity Btuh |
COP | |||||||
| 300 | 0.75 | 340 | 220 | 2.5 | 9,300 | 14.4 | 11,500 | 5.4 | Capillary Tube |
3.5 |
| 400 | 1.00 | 420 | 280 | 3.3 | 12,000 | 14.0 | 14,500 | 5.2 | ||
| 600 | 1.50 | 630 | 420 | 4.5 | 18,200 | 15.2 | 21,600 | 5.1 | ||
| 800 | 2.00 | 830 | 580 | 6.0 | 23,000 | 13.1 | 30,000 | 5.0 | ||
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature. Heating based upon 70°F DB, 59°F WB entering air temperature. Includes 475 Btu/1000 CFM fan heat and 140 watts/1000 CFM fan power, plus water pumping power. 208V data shown. 265V ratings may vary.
| Electrical Data | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Size (Tons) | Compressor Type |
Voltage Volt-Hz-Ph |
Voltage Limitations | Compressor | Total Amps |
Minimum Circuit Capacity |
MOPD | ||
| Min | Max | RLA | LRA | ||||||
| 300 (0.75) | Rotary T | 208-230/60/1 | 197 | 252 | - | - | See Calculation Note Below |
||
| 265/60/1 | 239 | 292 | - | - | |||||
| 400 (1.0) | 208-230/60/1 | 197 | 252 | 5.5 | 31.2 | ||||
| 265/60/1 | 239 | 292 | 5.5 | 27. | |||||
| 600 (1.5) | Reciprocating B | 208-230/60/1 | 197 | 252 | 7.1 | 44.0 | |||
| 265/60/1 | 239 | 292 | 9.0 | 44.0 | |||||
| Scroll C | 265/60/1 | - | - | - | - | ||||
| 800 (2.0) | Reciprocating B | 208-230/60/1 | 197 | 252 | 12.8 | 61.0 | |||
Use this value to calculate minimum power supply circuit ampacity (Clause 3.14 of UL1995 4th Ed) and maximum current rating of overcurrent protection (Clause 37.15 of UL1995 4th Ed). Note: Chassis Only - Does not include Fan/Motor or Electric Heat loads.
The Whalen VI series Version 0 replacement chassis is designed for Whalen VI units produced between 1979 and 1993. They are available in 200, 300, 400, 600 and 800 capacities. As part of a complete system, the Whalen VI Series Version 0 unit is engineered to fit into the existing cabinet space with matching electrical/water connections as the original unit.
Each unit utilizes energy efficient quality components and tested in our psychrometric room to confirm safety, reliability and performance at multiple operating conditions. The extensive list of unit features includes:
| Continuous Operating Limits | ||||||
|---|---|---|---|---|---|---|
| Mode | Ambient Air °F | Entering Air °F | ||||
| Min | Max | Min | Max | |||
| DB | DB | DB | WB | DB | WB | |
| Cooling | 60 | 100 | 75 | 63 | 100 | 83 |
| Heating | 60 | 80 | 60 | - | 80 | - |
| Unit Sizes | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model | H | W | D | CW | CH | OCH | Packaging Dimensions W × H × D |
Filter Size | Operating Weight / Shipping Weight |
| 200/300/400 | 25.0" | 13.8" | 14.0" | 11.4" | 12.0" | 16.0" | 14.3 × 16.3 × 28.0 | 13 × 24 × 1 | 79 / 118 |
| 300 | 25.0" | 13.8" | 14.0" | 11.4" | 14.0" | 18.0" | 81 / 120 | ||
| 300/400 | 25.0" | 13.8" | 14.0" | 11.4" | 18.0" | 22.0" | 83 / 122 | ||
| 400 | 25.0" | 13.8" | 14.0" | 11.4" | 20.0" | 24.0" | 83 / 122 | ||
| 600 | 27.3" | 13.8" | 16.0" | 11.4" | 18.0" | 22.0" | 16.5 × 19.3 × 1.0 | 13 × 32 × 1 | 123 / 160 |
| 600/800 | 27.3" | 13.8" | 16.0" | 11.4" | 24.0" | 28.0" | 132 / 170 | ||
| 800 | 27.3" | 13.8" | 16.0" | 11.4" | 28.0" | 32.0" | 132 / 170 | ||
| Performance Ratings | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model | Nominal Tonnage |
Rated CFM |
Minimum CFM |
GPM | Water Loop Heat Pump | Refrigerant Control |
Valve Flow Coefficient - Cv |
|||
| Cooling 86°F | Heating 68°F | |||||||||
| Capacity Btuh |
EER Btuh/W |
Capacity Btuh |
COP | |||||||
| 200 | 0.50 | 280 | 170 | 1.5 | - | - | - | - | Capillary Tube |
3.5 |
| 300 | 0.75 | 340 | 220 | 2.5 | 9,300 | 14.4 | 11,500 | 5.4 | ||
| 400 | 1.00 | 420 | 280 | 3.3 | 12,000 | 14.0 | 14,500 | 5.2 | ||
| 600 | 2.50 | 630 | 420 | 4.5 | 18,200 | 15.2 | 21,600 | 5.1 | ||
| 800 | 2.00 | 830 | 580 | 6.0 | 23,000 | 13.1 | 30,000 | 5.0 | ||
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature. Heating based upon 70°F DB, 59°F WB entering air temperature. Includes 475 Btu/1000 CFM fan heat and 140 watts/1000 CFM fan power, plus water pumping power. 208V data shown. 265V ratings may vary.
| Electrical Data | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Size (Tons) | Compressor Type |
Voltage Volt-Hz-Ph |
Voltage Limitations | Compressor | Total Amps |
Minimum Circuit Capacity |
MOPD | ||
| Min | Max | RLA | LRA | ||||||
| 200 (0.50) | Rotary T | 208-230/60/1 | 197 | 252 | - | - | See Calculation Note Below | ||
| 300 (0.75) | Rotary T | 115/60/1 | - | - | 8.9 | 50.0 | |||
| Rotary L | 208-230/60/1 | 197 | 252 | 4.9 | 25.0 | ||||
| Rotary T | 208-230/60/1 | - | - | 5.7 | 31.2 | ||||
| Rotary L | 265/60/1 | 239 | 292 | 3.5 | 22.0 | ||||
| Rotary T | 265/60/1 | - | - | 3.8 | 22.9 | ||||
| 400 (1.00) | Rotary L | 115/60/1 | - | - | - | - | |||
| Rotary T | 115/60/1 | - | - | 11.0 | 62.0 | ||||
| Rotary L | 208-230/60/1 | 197 | 252 | 4.1 | 22.0 | ||||
| Rotary T | 208-230/60/1 | - | - | 5.5 | 31.2 | ||||
| Rotary L | 265/60/1 | 239 | 292 | 4.2 | 22.0 | ||||
| Rotary T | 265/60/1 | - | - | 5.5 | 31.2 | ||||
| 600 (1.50) | Reciprocating B | 208-230/60/1 | 197 | 252 | 7.1 | 44.0 | |||
| Reciprocating C | 208-230/60/1 | - | - | 9.0 | 48.0 | ||||
| Reciprocating B | 265/60/1 | 239 | 292 | 6.2 | 44.0 | ||||
| Reciprocating C | 265/60/1 | - | - | 9.0 | 44.0 | ||||
| 800 (2.00) | Reciprocating B | 208-230/60/1 | 197 | 252 | 12.8 | 61.0 | |||
| Reciprocating B | 265/60/1 | 239 | 292 | 11.5 | 67.0 | ||||
Use this value to calculate minimum power supply circuit ampacity (Clause 3.14 of UL1995 4th Ed) and maximum current rating of overcurrent protection (Clause 37.15 of UL 1995 4th Ed). Note: Chassis Only - Does not include Fan/Motor or Electric Heat loads.
The Whalen VI series Version 1,2,3,4 replacement chassis is designed for Whalen VI units produced between 1993 to present. They are available in 200, 300, 400, 500, 600, 800, 1000 and 1200 capacities. As part of a complete system, the Whalen VI Series Version 1,2,3,4 unit is engineered to fit into the existing cabinet space with matching electrical/water connections as the original unit.
Each unit utilizes energy efficient quality components and tested in our psychrometric room to confirm safety, reliability and performance at multiple operating conditions. The extensive list of unit features includes:
| Continuous Operating Limits | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Mode | Ambient Air °F | Entering Air °F | Entering Fluid °F | |||||||
| Min | Max | Min | Max | Standard Range (Capillary Tube & TXV) |
Extended / Geo Range (TXV Only) |
|||||
| DB | DB | DB | WB | DB | WB | Min | Max | Min | Max | |
| Cooling | 60 | 100 | 75 | 63 | 100 | 83 | 60 | 120 | 30 | 120 |
| Heating | 60 | 80 | 60 | - | 80 | - | 60 | 90 | 20 | 90 |
Note: Extended/Geothermal Range require insulated components, correct control/jumper settings, and design condition antifreeze solution.
| Unit Sizes | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model | H (in) | W (in) | D (in) | CW (in) | CH (in) | OCH (in) | Packaging Dimensions W × H × D (in) |
Filter Size (in) | Unit Weight (lbs) |
| 200 | 21.1 | 13.8 | 15.0 | 11.4 | 12.0 | 16.0 | 14.3 × 16.3 × 28.0 | 13 × 24 × 1 | 79 |
| 300 | 21.1 | 13.8 | 15.0 | 11.4 | 14.0 | 18.0 | 14.3 × 16.3 × 28.0 | 13 × 24 × 1 | 81 |
| 200/300 | 21.1 | 13.8 | 15.0 | 11.4 | 18.0 | 22.0 | 14.3 × 16.3 × 28.0 | 13 × 24 × 1 | 81 |
| 300/400 | 21.1 | 13.8 | 15.0 | 11.4 | 20.0 | 24.0 | 14.3 × 16.3 × 28.0 | 13 × 24 × 1 | 83 |
| 600 | 23.1 | 15.8 | 18.0 | 13.4 | 20.0 | 24.0 | 16.5 × 19.3 × 32.0 | 15 × 28 × 1 | 123 |
| 500/600/800 | 23.1 | 15.8 | 18.0 | 13.4 | 24.0 | 28.0 | 16.5 × 19.3 × 32.0 | 15 × 28 × 1 | 132 |
| 1000/1200 | 25.0 | 17.8 | 20.3 | 15.4 | 28.0 | 33.4 | 20.0 × 21.0 × 42.8 | 17 × 32 x 1 17 x 40 × 1 |
165 |
| 810/1000/1200 | 25.0 | 17.8 | 20.3 | 15.4 | 36.0 | 41.8 | 20.0 × 21.0 × 42.8 | 17 × 40 × 1 | 175 |
| Unit Shipping | |||||
|---|---|---|---|---|---|
| Model | Single Unit | Multiple Units | |||
| Skid Size W × H × D (in) |
Total Skid Weight (lbs) |
Skid Size* W × H × D (in) |
Skid Weight** (lbs) |
Max Units (#) |
|
| 200 | 24 × 24 × 34 | 95 | 48 × 48 × 34 | 40 | 6 |
| 300 | 24 × 24 × 34 | 97 | 48 × 48 × 34 | 40 | 6 |
| 200/300 | 24 × 24 × 34 | 97 | 48 × 48 × 34 | 40 | 6 |
| 300/400 | 24 × 24 × 34 | 99 | 48 × 48 × 34 | 40 | 4 |
| 600 | 24 × 24 × 38 | 139 | 48 × 40 × 38 | 40 | 4 |
| 500/600/800 | 24 × 24 × 38 | 148 | 48 × 40 × 38 | 40 | 4 |
| 1000/1200 | 24 × 24 × 48 | 181 | 48 × 40 × 48 | 40 | 4 |
| 810/1000/1200 | 24 × 24 × 48 | 191 | 48 × 40 × 48 | 40 | 4 |
|
* Maximum skid size ** Total skid weight = (Number of Units × Unit Weight) + Skid Weight |
|||||
| Performance Ratings | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Nominal Tonnage |
Rated CFM |
Min. CFM |
GPM | Water Loop Heat Pump | Ground Loop Heat Pump | Refrigerant Control |
Valve Flow Coefficient - Cv |
||||||
| Cooling 86°F | Heating 68°F | Cooling 77°F | Heating 32°F | |||||||||||
| Capacity Btuh |
EER Btuh/W |
Capacity Btuh |
COP | Capacity Btuh |
EER Btuh/W |
Capacity Btuh |
COP | |||||||
| Nu - R-22 | ||||||||||||||
| 601 | 1.50 | 630 | 420 | 4.5 | 18,200 | 15.2 | 21,600 | 5.1 | 19,000 | 16.2 | 13,000 | 3.2 | Capillary Tube NU-22 |
3.5 |
| 801 | 2.00 | 830 | 580 | 6.0 | 23,000 | 13.1 | 30,000 | 5.0 | 25,000 | 14.5 | 19,000 | 3.2 | 3.5 | |
| 1001 | 2.50 | 970 | 650 | 7.5 | 29,200 | 14.2 | 35,900 | 5.0 | 29,700 | 15.5 | 22,000 | 3.2 | 5.0 | |
| Version 1,2,3,4 - R410A | ||||||||||||||
| 203/204 | 0.50 | 280 | 170 | 1.5 | 6,500 | 13.0 | 8,300 | 5.1 | 6,900 | 14.2 | 5,200 | 3.2 | R-410A | 3.5 |
| 303/304 | 0.75 | 340 | 220 | 2.5 | 9,300 | 14.4 | 11,500 | 5.4 | 9,650 | 15.4 | 6,850 | 3.3 | ||
| 403/404 | 1.00 | 420 | 280 | 3.3 | 12,000 | 14.0 | 14,500 | 5.2 | 12,700 | 16.0 | 9,400 | 3.3 | ||
| 503/504 | 1.25 | 540 | 380 | 3.9 | 14,600 | 16.7 | 18,400 | 6.0 | 15,200 | 17.7 | 11,000 | 3.5 | ||
| 603/604 | 1.50 | 630 | 420 | 4.5 | 18,200 | 15.2 | 21,600 | 5.1 | 19,000 | 16.2 | 13,000 | 3.2 | ||
| 803/804 | 2.00 | 830 | 580 | 6.0 | 23,000 | 13.1 | 30,000 | 5.0 | 25,000 | 14.5 | 19,000 | 3.2 | ||
| 813/814 | 2.00 | 830 | 580 | 6.0 | 25,000 | 14.8 | 30,000 | 5.0 | 26,000 | 15.7 | 19,000 | 3.2 | 5.0 | |
| 1003/1004 | 2.50 | 970 | 650 | 7.5 | 29,200 | 14.2 | 35,900 | 5.0 | 29,700 | 15.5 | 22,000 | 3.2 | ||
| 1203/1204 | 3.00 | 1170 | 750 | 9.0 | 33,100 | 14.2 | 42,000 | 5.2 | 33,600 | 15.3 | 25,400 | 3.3 | ||
Cooling based upon 80.6°F DB, 66.2°F WB entering air temperature. Heating based upon 70°F DB, 59°F WB entering air temperature. Includes 475 Btu/1000 CFM fan heat and 140 watts/1000 CFM fan power, plus water pumping power. 208V data shown. 265V ratings may vary.
| Electrical Data | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Size (Tons) | Compressor Type | Voltage Volt-Hz-Ph |
Voltage Limitations | Compressor | Total Amps | Min. Circuit Capacity | MOPD | ||
| Min | Max | RLA | LRA | ||||||
| 20x (0.5) | Rotary T | 208-230/60/1 | 197 | 252 | 2.5 | 17.7 | See Calculation Note Below |
||
| 265/60/1 | 239 | 292 | 2.6 | 13.5 | |||||
| 30x (0.75) | Rotary L | 208-230/60/1 | 197 | 252 | 5.1 | 22.0 | |||
| 265/60/1 | 239 | 292 | 4.5 | 22.0 | |||||
| 40x (1.0) | Rotary L | 208-230/60/1 | 197 | 252 | 6.4 | 25.0 | |||
| 265/60/1 | 239 | 292 | 5.1 | 22.0 | |||||
| 50x (1.25) | Rotary L | 208-230/60/1 | 197 | 252 | 4.8 | 26.0 | |||
| 265/60/1 | 239 | 292 | 4.2 | 25.0 | |||||
| 60x (1.5) | Rotary L | 208-230/60/1 | 197 | 252 | 7.7 | 38.0 | |||
| Scroll C | 208-230/60/1 | 197 | 252 | 7.0 | 38.0 | ||||
| Rotary L | 265/60/1 | 239 | 292 | 7.1 | 30.0 | ||||
| Scroll C | 265/60/1 | 239 | 292 | 6.0 | 30.0 | ||||
| 80x (2.0) | Rotary L | 208-230/60/1 | 197 | 252 | 10.3 | 43.0 | |||
| Scroll C | 208-230/60/1 | 197 | 252 | 13.5 | 58.0 | ||||
| Scroll C | 265/60/1 | 239 | 292 | 8.3 | 54.0 | ||||
| 81x (2.0) | Reciprocating B | 208-230/60/1 | 197 | 252 | 7.4 | 43.0 | |||
| Reciprocating B | 265/60/1 | 239 | 292 | 6.7 | 46.0 | ||||
| 100x (2.5) | Reciprocating B | 208-230/60/1 | 197 | 252 | 10.6 | 54.0 | |||
| Scroll C | 208-230/60/1 | 197 | 252 | 14.1 | 73.0 | ||||
| Scroll C | 265/60/1 | 239 | 292 | 11.2 | 60.0 | ||||
| Reciprocating B | 265/60/1 | 239 | 292 | 9.2 | 46.0 | ||||
| 120x (3.0) | Reciprocating B | 208-230/60/1 | 197 | 252 | 14.7 | 74.0 | |||
| Scroll C | 208-230/60/1 | 197 | 252 | 14.1 | 77.0 | ||||
| Scroll C | 265/60/1 | 239 | 292 | 12.2 | 72.0 | ||||
| Reciprocating B | 265/60/1 | 239 | 292 | 11.5 | 67.0 | ||||
Use this value to calculate minimum power supply circuit ampacity (Clause 3.14 of UL1995 4th Ed) and maximum current rating of overcurrent protection (Clause 37.15 of UL1995 4th Ed). Note: Chassis Only — Does not include Fan/Motor or Electric Heat loads.
The engineering and manufacturing of products that improve the quality of life for our customers. Our long-term commitment to this endeavor assures you of systems that are distinctive in concept, performance, reliability and value.
The number of industry “firsts” from Whalen is impressive.