Universe thermostat manual

VI Series

Heat Pump Chassis

Version 1, 2, 3, 4

(Click product name to see details)

VI Series Heat Pump Chassis - Version 1, 2, 3, 4

OEM Replacement Chassis

The Whalen VI series Version 1,2,3,4 replacement chassis is designed for Whalen VI units produced between 1993 to present. They are available in 200, 300, 400, 500, 600, 800, 1000 and 1200 capacities. As part of a complete system, the Whalen VI Series Version 1,2,3,4 unit is engineered to fit into the existing cabinet space with matching electrical/water connections as the original unit.

Each unit utilizes energy efficient quality components and tested in our psychrometric room to confirm safety, reliability and performance at multiple operating conditions. The extensive list of unit features includes:

Unit Sizes
Model H (in) W (in) D (in) CW (in) CH (in) OCH (in) Packaging Dimensions
W × H × D (in)
Filter Size (in) Unit Weight (lbs)
200 21.1 13.8 15.0 11.4 12.0 16.0 14.3 × 16.3 × 28.0 13 × 24 × 1 79
300 21.1 13.8 15.0 11.4 14.0 18.0 14.3 × 16.3 × 28.0 13 × 24 × 1 81
200/300 21.1 13.8 15.0 11.4 18.0 22.0 14.3 × 16.3 × 28.0 13 × 24 × 1 81
300/400 21.1 13.8 15.0 11.4 20.0 24.0 14.3 × 16.3 × 28.0 13 × 24 × 1 83
600 23.1 15.8 18.0 13.4 20.0 24.0 16.5 × 19.3 × 32.0 15 × 28 × 1 123
500/600/800 23.1 15.8 18.0 13.4 24.0 28.0 16.5 × 19.3 × 32.0 15 × 28 × 1 132
1000/1200 25.0 17.8 20.3 15.4 28.0 33.4 20.0 × 21.0 × 42.8 17 × 32 × 1
17 × 40 × 1
165
810/1000/1200 25.0 17.8 20.3 15.4 36.0 41.8 20.0 × 21.0 × 42.8 17 × 40 × 1 175
Performance Ratings
Model Nominal
Tonnage
Rated
CFM
Min.
CFM
GPM Water Loop Heat Pump Refrigerant
Control
Valve Flow
Coefficient – Cv
Cooling 86°F Heating 68°F
Capacity
Btuh
EER
Btuh/W
Capacity
Btuh
COP
601 1.50 630 480 4.5 18,000 15.0 21,000 5.0 TXV R-454b 3.5
801 2.00 830 630 6.0 23,000 13.0 27,000 4.5 3.5
1001 2.50 970 730 7.5 29,000 15.0 34,000 5.0 5.0
203/204 0.50 280 210 1.5 6,000 15.0 8,000 5.0 3.5
303/304 0.75 340 260 2.5 9,000 15.0 12,000 5.0 3.5
403/404 1.00 420 320 3.3 12,000 15.0 15,000 5.0 3.5
503/504 1.25 540 410 3.9 15,000 15.0 18,000 5.0 3.5
603/604 1.50 630 480 4.5 18,000 15.0 21,000 5.0 3.5
803/804 2.00 830 630 6.0 23,000 13.0 27,000 4.5 3.5
813/814 2.00 830 630 6.0 23,000 15.0 27,000 4.5 5.0
1003/1004 2.50 970 730 7.5 29,000 15.0 34,000 5.0 5.0
1203/1204 3.00 1170 880 9.0 35,000 15.0 41,000 5.0 5.0

Ratings allow for 475 Btu/1000 CFM fan heat and 140 watts/1000 CFM fan power, plus water pumping power.

Electrical Data
Size (Tons) Compressor Type Voltage
Volt-Hz-Ph
Voltage Limitations Compressor Total Amps Min. Circuit Capacity MOPD
Min Max RLA LRA
20x (0.5) Rotary 208-230/60/1 197 252 2.8 15.0 See Calculation
Note Below
265/60/1 239 292 2.2 14.0
30x (0.75) Rotary 208-230/60/1 197 252 4.0 22.0
265/60/1 239 292 4.0 23.0
40x (1.0) Rotary 208-230/60/1 197 252 4.6 25.0
265/60/1 239 292 3.9 21.0
50x (1.25) Rotary 208-230/60/1 197 252 5.2 26.0
265/60/1 239 292 4.7 21.0
60x (1.5) Rotary 208-230/60/1 197 252 6.6 36.0
265/60/1 239 292 5.4 27.0
80x (2.0) Rotary 208-230/60/1 197 252 8.9 43.0
Scroll 265/60/1 239 292 7.8 48.0
81x (2.0) Scroll 208-230/60/1 197 252 9.0 63.0
265/60/1 239 292 7.8 48.0
100x (2.5) Scroll 208-230/60/1 197 252 12.5 67.0
265/60/1 239 292 9.2 55.0
120x (3.0) Scroll 208-230/60/1 197 252 13.5 75.0
265/60/1 239 292 9.6 55.0

Use the compressor data to calculate minimum power supply circuit ampacity (UL 60335-2-40 Edition 4 Annex 101.DVB Clause 101.DVB.2) and maximum current rating of overcurrent protection (UL 60335-2-40 Edition 4 Annex 101.DVB Clause 101.DVB.3).
Note: Chassis Only - Does not include Fan/Motor or Electric Heat loads.

Unit Shipping
Model Single Unit Multiple Units
Skid Size
W × H × D (in)
Total Skid Weight
(lbs)
Skid Size*
W × H × D (in)
Skid Weight**
(lbs)
Max Units
(#)
200 24 × 24 × 34 95 48 × 48 × 34 40 6
300 24 × 24 × 34 97 48 × 48 × 34 40 6
200/300 24 × 24 × 34 97 48 × 48 × 34 40 6
300/400 24 × 24 × 34 99 48 × 48 × 34 40 4
600 24 × 24 × 38 139 48 × 40 × 38 40 4
500/600/800 24 × 24 × 38 148 48 × 40 × 38 40 4
1000/1200 24 × 24 × 48 181 48 × 40 × 48 40 4
810/1000/1200 24 × 24 × 48 191 48 × 40 × 48 40 4
* Maximum skid size
** Total skid weight = (Number of Units × Unit Weight) + Skid Weight
Continuous Operating Limits
Mode Ambient Air °F Entering Air °F Entering Fluid °F
Min Max Min Max Standard Range
(Capillary Tube & TXV)
Extended / Geo Range
(TXV Only)
DB DB DB WB DB WB Min Max Min Max
Cooling 60 100 75 63 100 83 60 120 30 120
Heating 60 80 60 - 80 - 60 90 20 90

Note: Extended/Geothermal Range require insulated components, correct control/jumper settings, and design condition antifreeze solution.

Benefits that Make a Big Difference

When you consider all of the features of Whalen units, it’s easy to see why they deliver so many benefits to contractors and users alike.

The Whalen VI series Version 1,2,3,4 is the only replacement chassis approved by the manufacturer to work with the existing blower section and control box wiring without modification. As an OEM replacement, each unit is built with equal or superior components as the original without the need to supply additional information.

Low Sound Level

The refrigeration chassis includes a compressor that incorporates engineered vibration isolators installed on a heavy gauge mounting base with a mounting system to maximize vibration dampening. A sound dampening enclosure constructed of heavy gauge metal lined with acoustical insulation encases the refrigeration circuit.

Fast and Easy Replacement

The refrigeration chassis consist of the compressor, air coil, water coil, reversing valve, expansion device, receiver, filter-dryer and safety controls designed for easy removal after disconnecting hoses and a polarized electrical power plug.

Damage Protection

Units are provided with high pressure and low temperature safety controls configured in a lockout circuit to prevent damage to the compressor. The compressors are wired with either internal or external overload protective devices.

Common Options Accessories*

*varies by project
Warranty

All units are provided with a 12-month warranty (from date of ship) for all components.

Note: The replacement chassis performance is based on providing the proper airflow through the new chassis. Existing fan assemblies affect airflow due to corrosion and caked-on dirt. Fan motors affect airflow due to age or improper specifications.

Cleaning/Repair/Replacement of blowers is required prior to installation of new chassis. New fan/motor assemblies allow your new replacement chassis to perform properly for years to come.

Behind every unit that carries the Whalen name is a singularity of purpose: the engineering and manufacturing of products that improve the quality of life for our customers.

Our long-term commitment to this endeavor assures you of systems that are distinctive in concept, performance, reliability and value.

The number of industry “firsts” from Whalen is impressive.

They include:

• The industry’s first vertical stack valveless fan coils

• The first vertical stack heat pump offering

• The first removable chassis closet-type heat pumps

• The first AHRI-listed water-cooled air conditioning units with hydronic heat

Let us put Whalen innovation to work for you, too. Find out how our approach to your project will deliver a “perfect fit” solution—and make your life easier.

Need to locate a sales representative?


Whalen’s sales rep locator tool was designed to help you easily find a Whalen sales representative within the United States and Canada.

whalencompany.com/replocator

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.